Abstract

Background: Roflumilast (ROF) is an antiasthmatic drug used frequently for treating chronic obstructive pulmonary disease (COPD). The various reported methods developed with a non-systematised traditional workframe for routine estimation of ROF in formulations indicated the demand for developing a systematised new method. 

Objective: In the present study, an attempt was made to develop a new validated liquid chromatographic method with federal flexibilities and stability-indicating potential.

Method: A time-efficient, rapid, and systematised quality by design (QbD) approach was developed to avail regulatory flexibilities with assured performance. Defining the analytical target profile (ATP) and associated critical analytical attributes (CAAs) helped control the method’s performance. Methanol proportion, flow rate, pH, and detection wavelength were the four identified critical method variables (CMVs) that were further studied for robustness investigation. Moreover, the control strategies for CMVs were defined as per method intent. Chromatography constituted methanol: water (pH 3.5 maintained by orthophosphoric acid) (90:10% v/v) as the mobile phase, flowing at 1.2 ml/min on a ShimPack GWS C18 column. The photodiode array (PDA) detector provided the best results at 250 nm.

Results: ROF was eluted at a retention time of 3.1 min with acceptable system suitability values. Validation studies postulated method acceptability and suitability. Results for parameters viz. linearity (0.5–160 µg/ml), accuracy (> 98%), and precision (< 1%) advocated method reliability. ROF was susceptible to applied acidic and alkaline stress, requiring adequate preventive measures during formulation development.

Conclusion: Overall, this method worked well for figuring out ROF even when there were product additives and possible degradation products present, showing that it can be used on a regular basis.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Keywords:

Control strategy, Degradation, Fishbone diagram, Liquid chromatography, Roflumilast

Published

2024-06-30

How to Cite

1.
Panda SS, Bera RKVV. Development and Validation of a Systematized Liquid Chromatographic Method for Estimation of Roflumilast in Tablets and in Presence of its Degradation Products. Scopus Indexed [Internet]. 2024 Jun. 30 [cited 2024 Jul. 4];17(3):7375-8. Available from: http://ijpsnonline.com/index.php/ijpsn/article/view/2790

Issue

Section

Research Articles

References

Siddiqui MR, AlOthman ZA, Rahman N. Analytical techniques in pharmaceutical analysis: a review. Arabian journal of chemistry. 2017 Feb;10(S1): S1409-1421.

Tushiram DG, Umamaheshwari D. Novel analytical techniques used in identification and isolation of impurities in pharmaceuticals an overview. Journal of pharmaceutical sciences & research. 2020 Jan; 12(1): 37-42.

Mathaes R, Narhi L, Hawe A, Matter A, Bechtold-Peters K, Kenrick S, Kar S, Laskina O, Carpenter J, Cavicchi R, Koepf E, Lewis NE, DeSilva R, Ripple D. Phase-appropriate application of analytical methods to monitor subvisible particles across the biotherapeutic drug product life cycle. The AAPS journal. 2020 Jan; 22:1.

Fatta D, Achilleos A, Nikolaou A, Meric S. Analytical method for tracing pharmaceutical residues in water and wastewater. TrAC Trends in analytical chemistry. 2007 Jun; 26(6): 515-533.

Panda SS, Bera VVRK, Beg S, Sahu SK, Muni S. Development and validation of stability-indicating liquid chromatographic method for estimating vilazodone hydrochloride in pharmaceutical dosage form using quality by design. Journal of chromatographic sciences. 2016 Nov 30; 54(10):1713-1722.

Beg S, Chaudhary V, Sharma G, Garg B, Panda SS, Singh B. QbD-oriented development and validation of a bioanalytical method for nevirapine with enhanced liquid-liquid extraction and chromatographic separation. Biomedical chromatography. 2016 Jun; 30(6): 818-828.

Beg S, Sharma G, Katare OP, Lohan S, Singh B. Development and validation of a stability-indicating liquid chromatographic method for estimating olmesartan medoxomil using quality by design. Journal of chromatographic science. 2015 Aug; 53(7): 1048-1059.

International conference on harmonization of technical requirements for registrationof pharmaceuticals for human use. Pharmaceutical development Q8. Harmonized tripartite guideline. 2009:1-28.

Panda SS, Beg S, Ravi kumar BVV, Rath J. Implementation of quality by design approach for developing chromatographic methods with enhanced method performance: a mini review. Journal of analytical & pharmaceutical research. 2016 Jul 29; 2(6):39-43.

Sweetman SC. Martindale: The Complete Drug Reference, 36th ed. London: Pharmaceutical Press; 2009. p. 1131.

Barhate VD, Deosthalee P. Rapid liquid chromatographic method for the determination of roflumilast in presence of degradation products. Indian journal of pharmaceutical sciences. 2010 May-Jun; 72(3): 401-404.

Barhate VD, Deosthalee PC. Validation of rapid liquid chromatographic method for the determination of roflumilast. Journal of chemical and pharmaceutical research. 2011 Mar-Apr; 3(2): 770-775.

Ladani JJ, Bhimani RD, Vyas KB, Nimavat KS. Analytical method development and validation of RP-HPLC for estimation of roflumilast in bulk drug and tablet dosage form. International journal for pharmaceutical research scholars. 2012 Jul;1(3): 28-32.

Yan W, Chen Y, Ni C, Zheng X. Identification and quantitative analysis of related substances in roflumilast. Chinese journal of pharmaceutical analysis. 2013 Jan 1;33(10): 1726-1730.

Shah AD, Patel CN. Implementation of QbD approach to the RP-HPLC method development and validation of roflumilast in bulk and tablet dosage form: an application in degradation study. World journal of pharmacy and pharmaceutical sciences. 2014 May 20; 3(6): 2281-2307.

Belal TS, Ahmed HM, Mahrous MS, Daabees HG, Baker MM. Validated stability-indicating HPLC-DAD method for determination of the phosphodiestarase (PDE-4) inhibitor roflumilast. Bulletin of faculty of pharmacy, cairo university. 2014 Jun; 52(1): 79-89.

Pinheiro MS, Marins RCE, Cabral LM, de Sousa V. Development and validation of a RP-HPLC method for roflumilast and its degradation products. Journal of liquid chromatography & related technology. 2018 Feb 23; 41(5): 223-231.

International conference on harmonization of technical requirements for registrationof pharmaceuticals for human use. Validation of analytical procedures: text and methodology Q2(R1). Harmonized tripartite guideline. 2005: 1-17.

Panda SS, Bera VVRK, Mohanta G, Dash R and Patel PK. New stability-indicating RP-UFLC method for determination of trospium chloride in tablet dosage form. Scientia pharmaceutica. 2012 Oct-Dec; 80 (4): 955-964.

Panda SS, Ravi kumar BVV, Patel PK and Panda JR. New RP-UFLC method for estimation of xanthinol nicotinate in pharmaceutical dosage form. Chemical science transactions 2013 Apr-Jun; 2 (2): 656-662.

Panda SS, Ravi Kumar BVV, Acharjya SK, Sahu K. RP-UFLC method for estimation of propafenone in tablets. International journal of pharmaceutical sciences and nanotechnology. 2014 Nov 30; 7(4): 2671-2676.

Suman G, Prajapati D. Control chart applications in healthcare: a literature review. International journal of metrology and quality engineering. 2018 May 18; 9(5):1-21.

Weirnimont G. Use of control charts in analytical laboratory. Industrial and engineering chemistry analytical edition. 1946 Oct 1; 18(10):587-592.

Moldoveanu SC, David V. Mobile Phases and Their Properties. In Essentials in Modern HPLC Separations. 2013 (pp. 363-443), Elsevier, Amsterdam.

Moldoveanu SC, David V. Stationary Phases and Columns for Chiral Chromatography. In Selection of the HPLC Method in Chemical Analysis. 2017 (pp. 363-276), Elsevier, Amsterdam.

Blessy M, Patel RD, Prajapati PN, Agrawal K. Development of forced degradation and stability indicating studies of drugs-a review. Journal of pharmaceutical analysis. 2014 Jun; 4(3): 159-165.

Sharma MK, Murugesan M. Forced degradation study and essential approach to develop stability indicating method. Journal of chromatography separation techniques. 2017 Jan 27; 8(1):1-3.

Aven T. Risk assessment and risk management: review of recent advances on their foundation. European journal of operational research. 2016 Aug 16; 253(1):1-13.

Andrade CL, De La O Herrera MA, Lemes EMB. A model of risk analysis in analytical methodology for biopharmaceutical quality control. PDA journal of pharmaceutical science and technology. 2018 May-Jun; 72 (3): 317-331.

Most read articles by the same author(s)